ADME S2 Column Example
ADME columns can deliver retention comparable to TFA-based methods while using formic acid mobile phases.

Application: Amino Acid Analysis Without TFA

https://images.openai.com/static-rsc-4/_sfPVO32ADznDY8zq5s4MDaBBDgpmGyCZ037l6h9u1AwrGiiKwZbeOYBD35A9nr6FIChPl0wd2FX_4w2vxLkkzaIRcLrvwu39V5FcpDOgQNW4Uy8B2CJXLI78jke-WRciQI3YZ1RH_5cy6PKfEM9zAyZZng1cweAJVvfH4R4lPZmbfr95FZjbZ5hwaBLf7U9?purpose=fullsize
https://images.openai.com/static-rsc-4/v4kjN8n91Ja_Dr0nAblyE3CFYf_M5XKAzBSVBhs8RSWM8K2i1-a27fAG12RB9XcCvz41d-CYgzAMiMYZunck6fjsVMTItxrik9VbCxQ-Lo2jhnYFDhOUVgXRjIHAZdP2o4duneN69t20Ff3e_GvFl5ZUD4cXtCzhBa4w5cOHw9Ols8LYum_jSGwBoA0ru2ls?purpose=fullsize

https://images.openai.com/static-rsc-4/_sfPVO32ADznDY8zq5s4MDaBBDgpmGyCZ037l6h9u1AwrGiiKwZbeOYBD35A9nr6FIChPl0wd2FX_4w2vxLkkzaIRcLrvwu39V5FcpDOgQNW4Uy8B2CJXLI78jke-WRciQI3YZ1RH_5cy6PKfEM9zAyZZng1cweAJVvfH4R4lPZmbfr95FZjbZ5hwaBLf7U9?purpose=fullsize

Challenge

Amino acids are highly polar compounds that are difficult to retain on conventional C18 columns under MS-compatible conditions.

  • With formic acid → poor retention
  • With TFA → improved retention, but:
    • Ion suppression
    • Poor MS sensitivity

Approach

Comparison of:

  • C18 column with formic acid
  • C18 column with TFA
  • ADME column with formic acid

Results (THIS is the key insight)

C18 + Formic Acid

  • Early elution of polar amino acids
  • Insufficient retention

C18 + TFA

  • Improved retention
  • Comparable separation
  • But not MS-friendly

ADME + Formic Acid

  • Strong retention of amino acids
  • Comparable to C18 + TFA
  • Fully compatible with LC-MS

👉 This is the money statement:

Retention comparable to TFA-based methods can be achieved using MS-friendly conditions.


Conclusion

ADME columns enable the analysis of polar compounds such as amino acids using formic acid mobile phases, achieving retention comparable to TFA-based methods while maintaining LC-MS compatibility.


AdmeApplication notesLc-ms