Description
Capcell Pak C18 MG series focuses on "versatility" and seeks to achieve a balance between hydrophobicity and surface polarity, the application of which is extended to the analysis of chelating compounds by using metal-free filling technology and surface processing. This C18 HPLC column can be applied to a wide range of compounds from low to high polarity.
Thanks to the polymer-coated base material and packing technology that take account of the influence of metallic impurities, CAPCELL PAK C18 MG sharply elutes even compounds with highly coordinating properties like hinokitiol. Moreover, since the packing material has been designed to enhance surface polarity, it firmly retains even compounds with polarity sites like coordinate compounds.
Features
-
From polar to hydrophobic compounds
Among C18 columns, MG column presents an intermediate level of hydrophobicity and surface polarity. It is the recommended column for a wide range of substances, from polar to hydrophobic compounds.
For coordinate compounds in particular, peak tailing and absorption have been minimized to enable elution with sharp peaks.
-
Coordinate compounds (hinokitiol) yet with a good peak profile
Thanks to the use of highly refined silica substrate and unique packing technology that minimized metallic impurity, the peaks of strong coordinate compounds like hinokitiol are eluted sharply. Because even trace amounts of metallic impurities greatly influence analysis results. Simply changing the column to MG will be your solution for absorption problem.
-
Good lot-to-lot reproducibility
Excellent lot-to-lot reproducibility has been achieved by Osaka Soda's silica gel manufacturing technology and column packing technology.
Excellent lot-to-lot reproducibility has been achieved by Osaka Soda's silica gel manufacturing technology and column packing technology.
Column | : | CAPCELL PAK C18 MG S2;2.0 mm i.d. x 50 mm |
---|---|---|
Mobile phase | : | 10 mmol/L HCOONH4/CH3OH = 95 / 5 |
Flow rate | : | 1 mL/min |
Temperature | : | 40℃ |
Detection | : | UV 254nm |
Inj. vol. | : | 1µL |
Sample | : | 1. Uridine 2. 2'-Deoxyuridine 3. Guanosine 4. 2'-Deoxyguanosine 5. 2'-Aminoadenosine 6. Adenosine (50 µg/mL each) |
-
With a particle size of 2μ, ultra-high-speed analysis is possible due to excellent separation performance.
Seven types of sulfa drugs were analyzed at ultra-high speed using CAPCELL PAK C18 MG S2. The full analysis is done within 1 minute and all compounds achieve baseline separation.
Column | : | CAPCELL PAK C18 MG S2;2.0 mm i.d. x 50 mm |
---|---|---|
Mobile phase | : | 20 mmol /L Phosphate buffer (KH2PO4 : K 2HPO4 = 1 / 1 in molar ratio) / CH3OH = 80 / 20 |
Flow rate | : | 900 µL/min |
Temperature | : | 40℃ |
Detection | : | UV 270nm |
Inj. vol. | : | 1µL |
Sample dissolved in | : | Mobile phase ※ 1 µg/mL = 1 ppm |
Sample | : | 1. Sulfanilamide 2. Sulfamethizole 3. Sulfamerazine 4. Sulfapyridine 5. Sulfamethoxypyridazine 6. Sulfamethazine 7. Sulfaquinoxaline |
Physical Properties
Functional group | Particle diameter (μm) |
Pore diameter (nm) |
Specific surface (m 2/g) |
C% | Density (µmol/m 2) |
pH range for use |
USP |
---|---|---|---|---|---|---|---|
Octadecyl group | 2 | 10 | 300 | 15 | 2.4 | 2~10 | L1 |
Octadecyl group | 3 | 10 | 300 | 16 | 2.6 | 2~10 | L1 |
Octadecyl group | 5 | 10 | 300 | 16 | 2.6 | 2~10 | L1 |