{"product_id":"1-mg-ml-stable-non-hygroscopic-karl-fischer-titrant-gfs-watermark","title":"1 mg\/mL Stable Non-Hygroscopic Karl Fischer Titrant | GFS Watermark","description":"\u003cdiv class=\"col-sm-12 ng-scope\"\u003e\n\u003cdiv class=\"ng-binding\"\u003e\n\u003cdiv class=\"col-sm-12 ng-scope\"\u003e\n\u003ch2 data-section-id=\"npqwrs\" data-start=\"845\" data-end=\"867\"\u003eProduct description\u003c\/h2\u003e\n\u003cp data-start=\"869\" data-end=\"1173\"\u003e\u003cstrong data-start=\"869\" data-end=\"938\"\u003eGFS Watermark 1 mg\/mL Stable Non-Hygroscopic Karl Fischer Titrant\u003c\/strong\u003e is a low-strength volumetric Karl Fischer titrant for moisture determination in compatible laboratory samples. The 1 mg\/mL concentration is useful when lower water levels, smaller sample sizes, or finer titration control are required.\u003c\/p\u003e\n\u003cp data-start=\"1175\" data-end=\"1486\"\u003eThis product is a \u003cstrong data-start=\"1193\" data-end=\"1222\"\u003eKarl Fischer titrant only\u003c\/strong\u003e and is intended for use with a compatible KF solvent or buffer system. It should not be described as a single-solution reagent. According to GFS Chemicals, this titrant must be used with KF Solvent 1609, 1610, or Buffer 1615. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1488\" data-end=\"1797\"\u003eThe stable, non-hygroscopic formulation is designed to support consistent titer strength and reliable volumetric Karl Fischer analysis. The GFS Watermark line includes multiple Karl Fischer reagent formats and titer strengths for different moisture analysis requirements. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1799\" data-end=\"2079\"\u003eFor samples containing aldehydes, ketones, or other reactive compounds, confirm reagent and solvent compatibility before analysis. Standard Karl Fischer reagent systems may be affected by side reactions and can produce inaccurate water results if the wrong reagent system is used.\u003c\/p\u003e\n\u003ch2 data-section-id=\"8xmrb8\" data-start=\"2081\" data-end=\"2099\"\u003eFeature bullets\u003c\/h2\u003e\n\u003cul data-start=\"2101\" data-end=\"2695\"\u003e\n\u003cli data-section-id=\"1cyjolm\" data-start=\"2101\" data-end=\"2170\"\u003e\n\u003cstrong data-start=\"2103\" data-end=\"2135\"\u003e1 mg\/mL Karl Fischer titrant\u003c\/strong\u003e for volumetric moisture analysis\u003c\/li\u003e\n\u003cli data-section-id=\"1lij6ie\" data-start=\"2171\" data-end=\"2240\"\u003eLower-strength titrant for finer control in suitable applications\u003c\/li\u003e\n\u003cli data-section-id=\"1lpmgvr\" data-start=\"2241\" data-end=\"2280\"\u003eStable, non-hygroscopic formulation\u003c\/li\u003e\n\u003cli data-section-id=\"bajd9w\" data-start=\"2281\" data-end=\"2330\"\u003eDesigned to support consistent titer strength\u003c\/li\u003e\n\u003cli data-section-id=\"150pzk0\" data-start=\"2331\" data-end=\"2388\"\u003eIntended for use with compatible KF solvent or buffer\u003c\/li\u003e\n\u003cli data-section-id=\"q38e98\" data-start=\"2389\" data-end=\"2457\"\u003eSuitable for routine volumetric Karl Fischer water determination\u003c\/li\u003e\n\u003cli data-section-id=\"ge969y\" data-start=\"2458\" data-end=\"2524\"\u003eManufactured by GFS Chemicals under the Watermark reagent line\u003c\/li\u003e\n\u003cli data-section-id=\"1n9x6tn\" data-start=\"2525\" data-end=\"2604\"\u003eNot a single-solution reagent; requires the proper solvent or buffer system\u003c\/li\u003e\n\u003cli data-section-id=\"rp26t4\" data-start=\"2605\" data-end=\"2695\"\u003eConfirm compatibility before analyzing aldehydes, ketones, or reactive sample matrices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"4z5xe\" data-start=\"2697\" data-end=\"2724\"\u003eTechnical note \/ caution\u003c\/h2\u003e\n\u003cp data-start=\"2726\" data-end=\"3028\"\u003e\u003cstrong data-start=\"2726\" data-end=\"2740\"\u003eImportant:\u003c\/strong\u003e This product is a Karl Fischer titrant and must be used with a compatible KF solvent or buffer. It should not be presented as a stand-alone single-solution reagent. Aldehydes and ketones may interfere with conventional Karl Fischer analysis unless the correct reagent system is selected.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 ng-scope\"\u003e\n\u003cdiv class=\"ng-scope\"\u003e\n\u003cdl\u003e\n\u003cdd class=\"ng-scope\"\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan class=\"ng-scope\"\u003e \u003cspan class=\"ng-binding\"\u003eAdditional Resources\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003ca class=\"button button--primary\" href=\"https:\/\/www.gfschemicals.com\/Portals\/0\/msds\/1602msds.pdf\" target=\"_blank\"\u003eSafety Data Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"GFS Chemicals","offers":[{"title":"Default Title","offer_id":43488424198299,"sku":"JM-821 MPN-99641-1602","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0481\/9497\/7947\/files\/placeholder_ebfd4308-99dd-4581-851d-94e533fc0abf.jpg?v=1691162596","url":"https:\/\/jmscience.com\/products\/1-mg-ml-stable-non-hygroscopic-karl-fischer-titrant-gfs-watermark","provider":"JM Science Inc","version":"1.0","type":"link"}