Description
OPTIZEN POP chooses our unique high resolving power wavelength measurement mechanism.
OPTIZEN POP Series are single-beam type spectrophotometers and offer stable performance and compact-size and reasonable price to the users. The series are categorized into POP, POP-S and POP-V according to the specification of the products.
OPTIZEN POP measures transmittance or absorbance for each wavelength of a sample in the ultraviolet and visible ray bands, and through this, quantitative characteristics such as concentration and purity can be identified.
OPTIZEN POP, which can be used widely from general analysis experiments to specialized research fields, guarantees accurate measurement and excellent reproducibility, providing reliable results in various fields such as environment, biotechnology, and chemistry.
OPTIZEN POP provides 4 measurement modes (Photometric Mode, Quantitation Mode, Spectrum Mode, Kinetics Mode), and the user can select and use the corresponding mode according to the purpose of measurement. Using the S/W built into the equipment, touch screen interface, and application software, it helps the user to use the equipment very easily.
-
User convenience
All functions of the existing PC software are loaded into OPTIZEN POP for faster and more convenient use. -
Amazing measurement speed
The fast and flexible software delivers the best results at analysis speeds up to 1.5 times faster than conventional products. -
Compact size
The compactly designed OPTIZEN POP increases the efficiency of the laboratory space. -
Prompt service
Based on OPTIZEN's proprietary technology, service is available from design to manufacturing in Korea. -
Wide scalability
Designed to enable high-precision/high-resolution measurement in a wide range from ultraviolet to visible light, it can be used in various application fields.
Product Function
- Help is presented in an easy-to-understand graphical format.
- If you register the information being measured, analyzed, or completed as a favorite, you can quickly and easily call it up and work with it.
- Can be used in conjunction with PC through OPTIZEN View
- It is possible to measure in an optimal state by checking the operating time of the equipment, the preheating status of the lamp, and the accumulated usage time in real time.
- It is possible to select the cell type and monitor the measurement without entering a mode, and the quick menu cell type icon changes depending on the cell type status or location, making it easy to check the current cell status.
- It employs a temperature measurement system as standard, allowing for temperature confirmation/recording at the moment of analysis.
- It supports convenient voice guidance and volume control function.
- It comes equipped with a multi-cell system as standard, enabling automatic measurement of a large quantity of samples.
Mode Descriptions
- This mode allows easy measurement of absorbance (Abs) (or transmittance (%T)) at a specific wavelength.
- You can set the factor (K) value, enabling simple quantitative analysis (C = K × A) of samples that are known only by absorbance (Abs) measurements.
- Up to 8 wavelengths can be set, and the absorbance at each wavelength is automatically measured.
- Using a multi-cell holder, automatic analysis of up to 7 samples is possible.
- This mode utilizes the multi-cell holder to measure and manage calibration curves.
- Quantitative analysis of target samples can be performed using a calibration curve constructed with up to 7 samples of different concentrations.
- Four types of calibration curves are available: Linear (Zero-crossing), Linear, Quadratic, and Cubic.
- Accurate calibration curves can be constructed using results that are measured up to 5 times.
- Through the Calibration Manager, you can use features such as selecting, creating, modifying, and deleting standard curves, as well as importing and exporting external Quantitation Mode files from external storage space.
- This mode allows users to view the spectrum of the desired wavelength range.
- Data conversion between absorbance (Abs) and transmittance (%T) is possible through shortcut keys.
- Automatic spectrum analysis of up to 7 samples (excluding reference sample) is possible.
- This mode includes features such as spectral zooming and finding the peak/valley positions in a spectrum.
- It is a mode that allows you to monitor the absorption (or transmittance) changes over time at a specific wavelength.
- It measures the absorbance (or transmittance) changes over time at a specific wavelength, and measurements are taken at regular time intervals. The minimum interval that can be set is 1 second.
- During the measurement, the progress rate is displayed, and measurement can be done up to a maximum of 24 hours.
- You can automatically acquire the absorbance changes of up to 7 samples.
According to the measurement range and conditions, the minimum measurement interval may be adjusted.
Features
- Single-beam Type
- Spectral Bandwidth : 1.8 nm
- Measurable Range : -3 A ~3 A
- 7" Display
- 8 Cell holder (Initially installed)
- Offering a help service with a graphic type.
- Easily and quickly call up the information that is being measured or analyzed by registering it in your favorites.
- Link it with PC by using OPTIZEN View.
- The measurement is possible in the optimal condition by checking the equipment’s operation time, lamp warm up condition and accumulated using time in real time.
- The measurement monitoring is possible through choosing cell type without entering a mode and easily checking the current cell condition is possible through a change cell type icon according to the cell type condition or position.
- Checking and recording the temperature at the analysis moment
by applying the temperature measurement system. - It can measure automatically lots of samples by using Multi Cell.
- Supporting convenient voice service and volume control function.
Specifications
Model | OPTIZEN POP |
Photometrics System | Single-beam type |
Light Source(s) | Tungsten Halogen Lamp & Deuterium Lamp (Built-in light source auto interchanging motor) |
Detector | Silicon Photodiode |
Spectral Bandwidth | < 1.8 nm |
Wavelength Range | 190 - 1100 nm |
Wavelength Display (setting) | ≥ 0.1 nm |
Wavelength Accuracy | < ± 0.5 nm (at D2 peak 656.1, 486.0 nm) |
Wavelength Repeatability | < ± 0.1 nm |
Slew Rate | About 7,800 nm/min |
Scanning Speed | max 4,000 nm/min |
Photometric Range | Absorbance : -3 A - 3 A / Transmittance : 0% - 300% |
Photometric Accuracy | < ± 0.005 A (at 1.0 A), < ± 0.003 A (at 0.5 A) |
Photometric Repeatability | < ± 0.001 A |
Baseline Stability | < ± 0.001 A/h (at 700 nm) |
Baseline Flatness | < ± 0.001 A (200 - 1100 nm) |
Stray Light | < 0.1%T (220, 340 nm) |
Monochromator | Czerny-Turner type with 1200 lines/nm blazed grating |
Standard Cell Holder | Automatic Rotary type 8-position Multi-Cell Holder |
Lamp Interchange Wavelength | 340 - 410 nm (Default 370 nm) |
Operating System (OS) | Windows® CE |
Display | 7 inch color LCD with touch screen |
Control Options | Onboard with built-in touchscreen, Computer |
Dimensions (W*D*H) | 433 mm*381 mm*180 mm |
Power Requirement | 100 - 240 V; 50 - 60 Hz |
Weight | 8 kg |
PC Software | (optional) OPTIZEN View for Windows® |
Model | OPTIZEN POP-V |
Photometrics System | Single-beam type |
Light Source(s) | Tungsten Halogen Lamp |
Detector | Silicon Photodiode |
Spectral Bandwidth | < 3.0 nm |
Wavelength Range | 340 - 1100 nm |
Wavelength Display (setting) | ≥ 0.1 nm |
Wavelength Accuracy | < ± 0.5 nm (at D2 peak 656.1, 486.0 nm) |
Wavelength Repeatability | < ± 0.2 nm |
Slew Rate | About 7,800 nm/min |
Scanning Speed | max 4,000 nm/min |
Photometric Range | Absorbance : -3 A - 3 A / Transmittance : 0% - 300% |
Photometric Accuracy | < ± 0.005 A (at 1.0 A), < ± 0.003 A (at 0.5 A) |
Photometric Repeatability | < ± 0.001 A |
Baseline Stability | < ± 0.002 A/h |
Baseline Flatness | < ± 0.003 A (340 - 1050 nm) |
Stray Light | < 0.1%T (220, 340 nm) |
Monochromator | Czerny-Turner type with 1200 lines/nm blazed grating |
Standard Cell Holder | Automatic Rotary type 8-position Multi-Cell Holder |
Lamp Interchange Wavelength | - |
Operating System (OS) | Windows® CE |
Display | 7 inch color LCD with touch screen |
Control Options | Onboard with built-in touchscreen, Computer |
Dimensions (W*D*H) | 433 mm*381 mm*180 mm |
Power Requirement | 100 - 240 V; 50 - 60 Hz |
Weight | 8 kg |
PC Software | (optional) OPTIZEN View for Windows® |