Description
The Chromaster 5420 UV-Vis Detector from Hitachi presents superior chromatography performance and portability, with a low dwell volume and minimal carry-over. This detector's advanced technology ensures heightened sensitivity for any application, from industrial processes to pharmaceutical analysis. Its modular design and range of accessories provide versatility and reliability.
Features
Low noise, low drift, and a high sensitivity detection
A noise level 0.5 × 10⁻⁵ AU*² (or less) can be achieved, allowing better sensitivity than ever. With a low drift of 1.0 × 10⁻⁴ AU / hr*³ (or less), these detectors deliver excellent baseline stability.
*2, 3 Under a specified condition
*2, 3 Under a specified condition
Two-wavelength simultaneous measurement function
The two-wavelength detection function*⁴ permits measurements at short data acquisition intervals of 400 ms*⁵ and 800 ms per wavelength. The result is chromatograms with sharp peak shapes.
*4 Controlled by CDS only
*5 400 ms is available only if the wavelength interval is 160 nm or less.
*4 Controlled by CDS only
*5 400 ms is available only if the wavelength interval is 160 nm or less.
Included Accessories
- AC Adapter
- Data Cable
- UI Pad
Product Specifications
Item | Specifications |
Optical system | Double-beam ratio photometric system |
Light source | D² lamp, W lamp, Hg lamp for checking wavelength |
Wavelength range | 190 nm to 900 nm |
Wavelength accuracy | ±1 nm |
Spectral bandwidth | 6 nm |
Noise | ≤−0.5 × 10⁻⁵ AU at 250 nm, 600 nm, under a specified condition |
Drift | ≤−1.0 × 10⁻⁴ AU/h at 250 nm, 600 nm, under a specified condition |
2-wavelength measurement |
2 wavelengths in wavelength regions 190 to 350 nm, 351 to 400 nm, 401 to 600 nm and 601 to 900 nm (D₂&W mode) 2 wavelengths in wavelength regions 190 to 350 nm and 351 to 600 nm (D₂ mode) 2 wavelengths in wavelength regions 380 to 600 nm and 601 to 900 nm (W mode) (Minimum wavelength interval 5 nm, max. wavelength interval 160 nm with data sampling period set at 400 ms) |
Response | 0.01, 0.02, 0.05, 0.1, 0.5, 1, 2 sec |
Materials of wetted parts | Quartz glass, Fluororesin, Stainless steel |
Functions of GLP | (a)D₂ lamp/W lamp/Hg lamp lighting time, lighting number of times, and replacement record (b)Key lock (c)D₂ lamp energy check and D₂ lamp wavelength check (d)W lamp energy check (e)Hg lamp wavelength check |
Flow cell | 13 μL (Optical path length 10 mm) |
Thermostatically flow cell | Optional, Environmental temperature range: 4 to 30°C |
Dimensions and weight | 340 (W) × 440 (D) × 140 (H) mm, Approx.14 kg |
Power supply and Power consumption |
DC24 V, 3.6 A (Maximum)/87 W (power supply from organizer) Please purchase the AC adaptor (150 W) when there is no organizer. |